Commit 072d957f for tesseract

commit 072d957f5553f92eab6563d1ad44dbedb3cebfb5
Author: Stefan Weil <sw@weilnetz.de>
Date:   Mon Sep 28 21:42:42 2026 +0200

    Fix heap overflow in intsimdmatrix_test when testing a wider kernel

    ExpectEqualResults sized the result buffer using the globally selected
    int8 kernel's RoundOutputs, but the kernel actually being tested may round
    the output to a larger size. The AVX512-VNNI kernel rounds outputs to a
    multiple of 16 while the default (AVX2) rounds to 8, so for num_out values
    where round_up(x,16) > round_up(x,8) the VNNI kernel wrote past the
    test_result buffer, corrupting the heap (glibc 'corrupted size vs.
    prev_size', abort) on the first such size.

    Size the buffer for the kernel under test instead of the global one.
    Production code is unaffected: it sizes v with the same kernel it calls.

    Assisted-by: OpenCode / qwen3.8-27b-thinking (Alibaba Cloud)
    Signed-off-by: Stefan Weil <sw@weilnetz.de>

diff --git a/unittest/intsimdmatrix_test.cc b/unittest/intsimdmatrix_test.cc
index b7bc1010..e1f32e7d 100644
--- a/unittest/intsimdmatrix_test.cc
+++ b/unittest/intsimdmatrix_test.cc
@@ -68,10 +68,11 @@ protected:
         GENERIC_2D_ARRAY<int8_t> w = InitRandom(num_out, num_in + 1);
         std::vector<int8_t> u = RandomVector(num_in, matrix);
         std::vector<TFloat> scales = RandomScales(num_out);
-        int ro = num_out;
-        if (IntSimdMatrix::intSimdMatrix) {
-          ro = IntSimdMatrix::intSimdMatrix->RoundOutputs(ro);
-        }
+        // The kernel under test may round the output to a different size than
+        // the globally selected one, so size the result buffer for it.
+        int ro = matrix.matrixDotVectorFunction != nullptr
+                     ? matrix.RoundOutputs(num_out)
+                     : num_out;
         std::vector<TFloat> base_result(num_out);
         IntSimdMatrix::MatrixDotVector(w, scales, u.data(), base_result.data());
         std::vector<TFloat> test_result(ro);